- Guaranteed Secure Payments on Every Order
- Refund if your item is not delivered or as described
- Buyer Protection after order confirmation
- Size: 1000
- Place of Origin: China
- Brand Name: QINSUN
- Model Number: Carpet Flammability Tester
- Weight: 1000.000 kg
Features:
1. Complete with measuring grid and clamping ring;
2. Sliding panel for easy access;
3. Angled mirror for viewing;
4. Applicable to 2 different tests, enclosed unit for optimum;
5. Safety.
Test Method:
The stainless steel nut is heated to a temperature of 900°C in a muffle furnace. The specimen is placed inside the test chamber and the clamping rig is placed onto the sample using crucible tongs supplied. The heated nut is placed in the centre of the clamping rig. After 30 seconds the nuts removed and the effects of the ignition allowed to subside. Measurements are then made to assess the spread of the ignition on the sample. It is recommended that the test chamber is placed in a laboratory fume hood. The conditioned specimens are placed on the removable base inside the test chamber and the metal plate with a circular cut-out is placed on the sample. The tablet is placed at the centre of the specimen and ignited. After the flame has extinguished, measurements are taken to assess the effects.
Consumables:
- Test Chamber(includes furnace)
- Accessories for Hot Nut Test
- Accessories for Methanamine Tablet Test
- M16 Nut for Hot Nut Test
- Methylamine Tablets for Methylamine Tablets Test
- Size: 1000
- Place of Origin: China
- Brand Name: QINSUN
- Model Number: Carpet Flammability Tester
- Weight: 1000.000 kg
Features:
1. Complete with measuring grid and clamping ring;
2. Sliding panel for easy access;
3. Angled mirror for viewing;
4. Applicable to 2 different tests, enclosed unit for optimum;
5. Safety.
Test Method:
The stainless steel nut is heated to a temperature of 900°C in a muffle furnace. The specimen is placed inside the test chamber and the clamping rig is placed onto the sample using crucible tongs supplied. The heated nut is placed in the centre of the clamping rig. After 30 seconds the nuts removed and the effects of the ignition allowed to subside. Measurements are then made to assess the spread of the ignition on the sample. It is recommended that the test chamber is placed in a laboratory fume hood. The conditioned specimens are placed on the removable base inside the test chamber and the metal plate with a circular cut-out is placed on the sample. The tablet is placed at the centre of the specimen and ignited. After the flame has extinguished, measurements are taken to assess the effects.
Consumables:
- Test Chamber(includes furnace)
- Accessories for Hot Nut Test
- Accessories for Methanamine Tablet Test
- M16 Nut for Hot Nut Test
- Methylamine Tablets for Methylamine Tablets Test